Precision-digital PD6200 User Manual Page 72

  • Download
  • Add to my manuals
  • Print
  • Page
    / 108
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 71
Model PD6200 Analog Input Rate/Totalizer Instruction Manual
72
Advanced Features Menu & Display Messages
The following table shows the functions and messages of the Advanced
Features
menu in the order they appear in the menu.
Display Parameter Action/Setting
filtr
Filter
Set noise filter value
bypASs
Bypass
Set filter bypass value
seriAl
Serial
Set serial communication parameters
SlaveId
Slave ID
Set slave ID or meter address
baud
Baud rate
Select baud rate
Tr dLY
Transmit delay
Set transmit delay for serial communication
Parity
Parity
Select parity
Even, Odd, or None with 1 or 2 stop bits
t-byt
Time byte
Set byte-to-byte timeout
SelEct
Select
Enter the Select menu (function, cutoff, out)
Functn
Signal input
conditioning
Select linear, square root, programmable
exponent, or round horizontal tank function
Linear
Linear
Set meter for linear function and select
number of linearization points
No PtS
Number of
points
Set meter for 2 to 32-point linearization
CutofF
Cutoff
Set low-flow cutoff
Square
Square root
Set meter for square root extraction
Prog E
Programmable
exponent
Set meter for programmable exponent and
enter exponent value
rht
Round horizon-
tal tank
Set meter for round horizontal tank volume
calculation
inCh
Dimension(cm)
Calculate volume in gallons or meters
diamr
Diameter
Enter the tank’s diameter in inches
Length
Length
Enter the tank’s length in inches
CutofF
Cutoff
Set low-flow cutoff
AoutPr
Analog output
programming
Program analog output parameters
Source
Source
Select source for the 4-20 mA output
Page view 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 107 108

Comments to this Manuals

No comments